FMCSA Section 5.1–5.2 dual air-brake component specs
FMCSA CDL Manual Sections 5.1 and 5.2 trace compressed air from the engine-driven compressor through dual primary/secondary circuits down to each wheel’s foundation drum or disc.
- Air Compressor & Governor: Governor cuts compressor IN around 100 psi and cuts OUT around 125 psi (120–140 psi typical system band)
- Storage Tanks & Safety Relief Valve: Wet/supply tank relief valve pops open at 150 psi if a stuck governor lets system pressure runaway
- Daily Tank Drains & Alcohol Evaporator: Expel water and compressor oil sludge that could freeze air valves solid in winter sub-zero weather
- Slack Adjusters & S-Cam Drums: Manual slack adjusters require service if pushrod stroke exceeds ~1 inch under firm pedal application
- Spring Brake Chambers: Powerful mechanical coil springs apply emergency/parking brakes mechanically whenever air pressure bleeds out